Current position: Home > Circuit Diagram > CARRIER-OPERATED RELAY

CARRIER-OPERATED RELAY


MPS-A55 MPS-A10 C106Y2

A shows a COR/CAS circuit for repeater use. CR1 is a silicon diode. K2 may be any relay with a 12-V coil (a long-life reed relay is best). R2 sets the length of time that K2 remains closed after the input voltage disappears(hang time). B shows atimer circuit. Values shown for R1 and C1 should provide timing up to four minutes or so. C1 should be a low-leakage capacitor; Q1 is a silicon-controled rectifier, ECG-5452 or equivalent. K1 may be any miniature relay with a 12-volt coil. The timer is reset when the supply voltage is momentarily interrupted. The switch must be in the RESET position for the remote reset to work. This circuit operates from the detector output of a receiver. A delay circuit is included so that the relay stays closed for a time period after the carrier output from the receiver disappears.

               
Do you need to purchase?
Do you need to purchase
MPS-A55 MPS-A10 C106Y2 ?
Post your buying lead to settle your difficult purchasing problem.

 
About Us  |  Contact us   |  Map  |  Link   |  Custom PCB Prototype Manufacturer